Test Code GLU Glucose, Plasma or Serum

Specimen Requirements

Submit only 1 of the following specimens:

 

Plasma
Draw blood in a green-top (lithium heparin) tube(s) or a plasma gel tube(s). Spin down within 2 hours of draw, and send 1 mL of lithium heparin plasma refrigerated.

Note:  1. Indicate plasma on request form.

2. Label specimen appropriately (plasma).

 

Serum

Draw blood in a plain, red-top tube(s) or a serum gel tube(s). Spin down within 2 hours of draw, and send 1 mL of serum refrigerated.

Note:  1. Indicate serum on request form.

2. Label specimen appropriately (serum).

Performing Laboratory

Conway Regional Clinical Laboratory Services

Reference Values

0-1 year:  70-123 mg/dL
≥1-2 years:  56-145 mg/dL
≥2 years:  70-105 mg/dL
Critical values (automatic call-back)

0-1 year:  <40 mg/dL or >200 mg/dL

≥2 years:  <40 mg/dL or >450 mg/dL 

Note:  Glycolysis due to failure to refrigerate specimen or to send it to the laboratory immediately may result in false-negative results. Failure to observe dietary restrictions may elevate glucose levels.

Methodology

Hexokinase, Ultraviolet

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

82947